File(s) | Type | Description | Action |
---|---|---|---|
pH.csv (878.05 KB) | Comma Separated Values (.csv) | Primary data file for dataset ID 847923 | Add to Cart Download |
This dataset includes pH from microsensor profiles of ex situ sediment cores collected in the Chesapeake Bay and measured during 2017-2018.
Methodology:
High-resolution microsensor profiling of O₂, pH, and H₂S was performed on replicate sediment cores retrieved from the sampling sites, with 1 or 2 replicate profiles made per sediment core per analyte, using commercial microsensors operated with a motorized micromanipulator (Unisense A.S., Denmark). pH sensors were calibrated with a 3-point NBS buffer calibration. Detailed methodology is given in Malkin et al., 2014.
Sampling and Analytical Procedures:
Replicate sediment cores were collected using a gravity corer (Uwitec; clear PVC liners, Ø = 8.6 cm), capped, kept in the dark at bottom water temperature in a water bath, and transported back to the laboratory, where they were held in a climate-controlled room. Microsensor profiling was conducted within 1 day of core retrieval.
Instruments:
Unisense A.S. microsensors (Denmark) and motorized micromanipulator system were used for data collection. The 4 channel microsensor multimeter was used, with the following microsensors: Ox-50, pH-200, and H2S-100. Each sensor was used consecutively and so resultant data is provided separately as individual datasets. SensorTrace Suite software was used for data collection.
Malkin, S. (2021) pH from microsensor profiles of ex situ sediment cores collected in the Chesapeake Bay and measured during 2017-2018. Biological and Chemical Oceanography Data Management Office (BCO-DMO). (Version 1) Version Date 2021-04-07 [if applicable, indicate subset used]. doi:10.26008/1912/bco-dmo.847923.1 [access date]
Terms of Use
This dataset is licensed under Creative Commons Attribution 4.0.
If you wish to use this dataset, it is highly recommended that you contact the original principal investigators (PI). Should the relevant PI be unavailable, please contact BCO-DMO (info@bco-dmo.org) for additional guidance. For general guidance please see the BCO-DMO Terms of Use document.