File(s) | Type | Description | Action |
---|---|---|---|
140410_Huettel.dat (695.04 MB) | Octet Stream | Current flow and oxygen concentrations recorded by the 2OEC-instrument from April 10-11, 2014 Time of first measurement 10 Apr. 2014, 10:00:00 Time of last measurement 11 Apr. 2014, 14:32:42 Number of measurements 6,576,690 Data file (data) Col# Parameter (Unit) 1 Seconds (s) 2 Day (Day in April 2014) 3 Burst counter (counts) 4 Ensemble counter (counts) 5 Velocity (Beam1|X|East) (m/s) 6 Velocity (Beam2|Y|North) (m/s) 7 Velocity (Beam3|Z|Up) (m/s) 8 Amplitude (Beam1) (counts) 9 Amplitude (Beam2) (counts) 10 Amplitude (Beam3) (counts) 11 SNR (Beam1) (dB) 12 SNR (Beam2) (dB) 13 SNR (Beam3) (dB) 14 Correlation (Beam1) (%) 15 Correlation (Beam2) (%) 16 Correlation (Beam3) (%) 17 Pressure (dbar) 18 Analog input 1 (counts) 19 Analog input 2 (counts) 20 Checksum (1=failed) Vector (Nortek) Accuracy: ± 0.5% of measured value ±1 mm/s Velocity precision: typ. 1% of velocity range (at 16 Hz) Oxygen sensor (Pyroscience) Accuracy at 5% a.s./0.44 mg/L ±0.1% a.s. ±0.01 mg/L at 95% a.s./8.8 mg/L ±1% a.s. ±0.1 mg/L Resolution at 5% a.s./0.44 mg/L 0.05% a.s. 0.005 mg/L at 95% a.s./8.8 mg/L 0.25% a.s. 0.025 mg/L Detection Limit 0.1% a.s. 0.01 mg/L | Add to Cart Download |
130816_Huettel.dat (602.87 MB) | Octet Stream | Current flow and oxygen concentrations recorded by the 2OEC-instrument from August 16-17, 2013. Time of first measurement 16 Aug. 2013, 10:30:00 Time of last measurement 17 Aug. 2013, 11:23:24 Number of measurements 5,734,705 Data file (data) Col# Parameter (Unit) 1 Seconds (s) 2 Day (Day in August 2013) 3 Burst counter (counts) 4 Ensemble counter (counts) 5 Velocity (Beam1|X|East) (m/s) 6 Velocity (Beam2|Y|North) (m/s) 7 Velocity (Beam3|Z|Up) (m/s) 8 Amplitude (Beam1) (counts) 9 Amplitude (Beam2) (counts) 10 Amplitude (Beam3) (counts) 11 SNR (Beam1) (dB) 12 SNR (Beam2) (dB) 13 SNR (Beam3) (dB) 14 Correlation (Beam1) (%) 15 Correlation (Beam2) (%) 16 Correlation (Beam3) (%) 17 Pressure (dbar) 18 Analog input 1 (counts) 19 Analog input 2 (counts) 20 Checksum (1=failed) Vector (Nortek) Accuracy: ± 0.5% of measured value ±1 mm/s Velocity precision: typ. 1% of velocity range (at 16 Hz) Oxygen sensor (Pyroscience) Accuracy at 5% a.s./0.44 mg/L ±0.1% a.s. ±0.01 mg/L at 95% a.s./8.8 mg/L ±1% a.s. ±0.1 mg/L Resolution at 5% a.s./0.44 mg/L 0.05% a.s. 0.005 mg/L at 95% a.s./8.8 mg/L 0.25% a.s. 0.025 mg/L Detection Limit 0.1% a.s. 0.01 mg/L | Add to Cart Download |
130814_Huettel.dat (784.98 MB) | Octet Stream | Current flow and oxygen concentrations recorded by the 2OEC-instrument from August 14-15, 2013. Time of first measurement 14 Aug. 2013, 10:30:00 Time of last measurement 15 Aug. 2013, 14:14:58 Number of measurements 6,393,542 Data file (data) Col# Parameter (Unit) 1 Seconds (s) 2 Day (Day in August 2013) 3 Burst counter (counts) 4 Ensemble counter (counts) 5 Velocity (Beam1|X|East) (m/s) 6 Velocity (Beam2|Y|North) (m/s) 7 Velocity (Beam3|Z|Up) (m/s) 8 Amplitude (Beam1) (counts) 9 Amplitude (Beam2) (counts) 10 Amplitude (Beam3) (counts) 11 SNR (Beam1) (dB) 12 SNR (Beam2) (dB) 13 SNR (Beam3) (dB) 14 Correlation (Beam1) (%) 15 Correlation (Beam2) (%) 16 Correlation (Beam3) (%) 17 Pressure (dbar) 18 Analog input 1 (counts) 19 Analog input 2 (counts) 20 Checksum (1=failed) Vector (Nortek) Accuracy: ± 0.5% of measured value ±1 mm/s Velocity precision: typ. 1% of velocity range (at 16 Hz) Oxygen sensor (Pyroscience) Accuracy at 5% a.s./0.44 mg/L ±0.1% a.s. ±0.01 mg/L at 95% a.s./8.8 mg/L ±1% a.s. ±0.1 mg/L Resolution at 5% a.s./0.44 mg/L 0.05% a.s. 0.005 mg/L at 95% a.s./8.8 mg/L 0.25% a.s. 0.025 mg/L Detection Limit 0.1% a.s. 0.01 mg/L | Add to Cart Download |