CTD data from AT39-01 (North Pond 2017 expedition).
CTD data from AT39-01 (North Pond 2017 expedition)
Cast at3901001 was a test cast. No bottles were fired. Pumps were turned on at a depth of approximately 27 meters. Data above this depth should not be considered valid and were removed before submission. The oxygen sensor encountered at problem at approximately 310 meters on the upcast. Oxygen data should not be considered valid between this depth and the end of the cast at 100 meters. Only the downcast data is provided here.
On cast at3901002, fouling caused intermittent pump operation in the plumbing line between the Temp1, Cond1, and Oxygen sensors. These data were manually replaced with 9.99e-29. Data from Temp2, Cond2, and all other sensors is valid for this cast.
On cast at3901009, a noticeable offset was present in the Oxygen data for the upcast, following a prolonged (12+ hour) deployment. The sensor was cleaned following the cast and values returned to normal on all subsequent casts. Only the downcast data is provided here
Steward, G. (2019) CTD data from AT39-01 (North Pond 2017 expedition) from the R/V Atlantis in the central North Atlantic during October 2017. Biological and Chemical Oceanography Data Management Office (BCO-DMO). (Version 1) Version Date 2019-03-07 [if applicable, indicate subset used]. doi:10.1575/1912/bco-dmo.757722.1 [access date]
Terms of Use
This dataset is licensed under Creative Commons Attribution 4.0.
If you wish to use this dataset, it is highly recommended that you contact the original principal investigators (PI). Should the relevant PI be unavailable, please contact BCO-DMO (info@bco-dmo.org) for additional guidance. For general guidance please see the BCO-DMO Terms of Use document.